ADJ30=0, RESET=0, HR24=0, AADJP=0, RTCOE=0, AADJE=0, CNTMD=0, START=0
RTC Control Register 2
START | Start 0 (0): Prescaler and time counter are stopped. 1 (1): Prescaler and time counter operate normally. |
RESET | RTC Software Reset 0 (0): Writing is invalid.(write) / In normal time operation, or an RTC software reset has completed.(read) 1 (1): The prescaler and the target registers for RTC software reset *1 are initialized.(write) / During an RTC software reset.(read) |
ADJ30 | 30-Second Adjustment 0 (0): Writing is invalid.(write) / In normal time operation, or 30-second adjustment has completed.(read) 1 (1): 30-second adjustment is executed.(write) / During 30-second adjustment.(read) |
RTCOE | RTCOUT Output Enable 0 (0): RTCOUT output disabled. 1 (1): RTCOUT output enabled. |
AADJE | Automatic Adjustment Enable (When the LOCO clock is selected, the setting of this bit is disabled.) 0 (0): Automatic adjustment is disabled. 1 (1): Automatic adjustment is enabled. |
AADJP | Automatic Adjustment Period Select (When the LOCO clock is selected, the setting of this bit is disabled.) 0 (0): The RADJ.ADJ[5:0] setting value is adjusted from the count value of the prescaler every minute. 1 (1): The RADJ.ADJ[5:0] setting value is adjusted from the count value of the prescaler every 10 seconds. |
HR24 | Hours Mode 0 (0): The RTC operates in 12-hour mode. 1 (1): The RTC operates in 24-hour mode. |
CNTMD | Count Mode Select 0 (0): The calendar count mode. 1 (1): The binary count mode. |